VBUS.CAP

Description

This parameter reports the DC bus capacitance for the drive. The capacitance value is determined by the drive model.

Examples

Usage

VBUS.CAP is used to calculate bus voltage ripple and detect phase loss at the AC line input to the DC bus. When phase loss is detected, the drive reported Fault "F2008": Bus capacitor overloaded.

Versions

Action Version Notes
Implemented 02-00-00-000

General Information

Type

Read Only

Units

microfarads

Range

N/A

Default Value

N/A

Data Type

Integer

See Also

N/A

Stored in Non-Volatile Memory

No

Variants Supported

All variants are supported.

Industrial Ethernet Information

EtherCAT CoE and CANopen

Command

Index

SubIndex

Data Type

Units

Float Scale

Access

PDO Mappable

VBUS.CAP

300ah

0bh

Unsigned16

-

-

Read only

No

EtherNet/IP

ID

Instance

Attribute

Name

Data Type

Access

User Mappable

2501

1

2501 (0x9c5)

VBUS.CAP

Unsigned32

Read Only

Yes

PROFINET

Parameter

PNU

Data Type

Access

Units

VBUS.CAP

2501

Unsigned32

Read Only

-